#PDB cf residue atom bb_p bb_s bb_f chi_p chi_s HB-D HB-I REF pred #--------------------------------------------------------------------------------------------- 2gwp n LEU 2 N 0.00 2.39 -4.75 0.99 4.77 -1.26 -4.58 117.00 114.56 2gwp n LEU 2 Ca 0.00 0.23 -0.40 0.00 -0.03 0.00 0.00 56.01 55.81 2gwp n LEU 2 Cb 0.00 -1.01 -0.05 0.00 -2.33 0.00 0.00 43.42 40.03 2gwp n LEU 2 CO 0.00 0.67 0.56 -0.76 -1.33 0.00 0.00 177.39 176.53 2gwp s LEU 3 N -7.26 4.55 0.28 2.23 1.02 -1.26 -4.98 118.68 113.27 2gwp s LEU 3 Ca -0.28 1.70 -0.11 0.00 0.02 0.00 0.00 54.13 55.46 2gwp s LEU 3 Cb 0.08 -3.41 -0.07 0.00 0.02 0.00 0.00 46.19 42.80 2gwp s LEU 3 CO 0.66 0.09 0.62 0.00 0.02 0.00 0.00 176.35 177.74 2gwp s TYR 5 N -1.95 1.61 0.20 0.00 -0.85 0.15 -4.90 117.35 111.61 2gwp s TYR 5 Ca 0.49 -0.60 -0.27 0.00 -0.52 0.00 0.00 57.07 56.17 2gwp s TYR 5 Cb -0.11 -0.77 -0.08 0.00 0.38 0.00 0.00 41.96 41.38 2gwp s TYR 5 CO 0.22 0.29 0.84 0.00 -1.52 0.00 0.00 175.55 175.39 2gwp s ARG 7 N -1.23 0.37 0.36 0.00 3.52 0.41 -4.97 118.95 117.41 2gwp s ARG 7 Ca 0.39 0.65 -0.26 0.00 -0.13 0.00 0.00 55.73 56.37 2gwp s ARG 7 Cb -0.24 0.04 -0.09 0.00 -1.56 0.00 0.00 34.95 33.10 2gwp s ARG 7 CO 0.28 -0.12 1.13 0.15 -0.81 0.00 0.00 175.30 175.93 2gwp s LYS 8 N 0.96 4.26 0.00 5.12 1.02 -1.26 0.14 119.74 129.97 2gwp s LYS 8 Ca -0.06 1.77 0.00 0.00 0.02 0.00 0.00 55.97 57.70 2gwp s LYS 8 Cb -0.07 -2.81 0.00 0.00 -0.52 0.00 0.00 37.83 34.44 2gwp s LYS 8 CO -0.07 -0.12 0.00 0.41 -0.92 0.00 0.00 175.35 174.64 2gwp n GLY 9 N 0.73 1.57 3.89 -3.33 0.00 0.50 -4.80 105.19 103.75 2gwp n GLY 9 Ca 0.03 -0.03 -0.00 0.00 0.00 0.00 0.00 46.02 46.02 2gwp n GLY 9 CO 0.00 0.00 0.00 0.30 0.00 0.00 0.00 173.32 173.62 2gwp s HIS 10 N 0.00 0.03 0.90 1.61 3.76 -1.26 -4.83 115.29 115.50 2gwp s HIS 10 Ca 0.00 -0.27 -0.12 0.00 -0.15 0.00 0.00 55.06 54.52 2gwp s HIS 10 Cb 0.00 0.62 0.13 0.00 1.11 0.00 0.00 32.58 34.44 2gwp s HIS 10 CO 0.00 -0.57 1.11 0.00 -0.85 0.00 0.00 174.74 174.43 2gwp s LYS 12 N -5.10 4.11 -0.62 0.00 2.47 -1.26 -4.89 119.74 114.45 2gwp s LYS 12 Ca 0.63 1.41 -0.26 0.00 -1.56 0.00 0.00 55.97 56.19 2gwp s LYS 12 Cb -0.16 -2.40 -0.09 0.00 -1.46 0.00 0.00 37.83 33.72 2gwp s LYS 12 CO 0.55 -0.17 2.36 0.50 0.16 0.00 0.00 175.35 178.75 2gwp s ARG 13 N -2.74 1.96 0.00 4.03 3.00 -1.26 -0.36 118.95 123.58 2gwp s ARG 13 Ca 0.60 0.97 0.00 0.00 -1.00 0.00 0.00 55.73 56.30 2gwp s ARG 13 Cb -0.19 -4.66 0.00 0.00 0.00 0.00 0.00 34.95 30.10 2gwp s ARG 13 CO 0.23 -3.68 0.00 0.41 0.00 0.00 0.00 175.30 172.26 2gwp n GLY 14 N 6.31 1.31 3.60 8.12 0.00 -1.26 -5.02 105.19 118.25 2gwp n GLY 14 Ca 0.40 0.00 -0.30 0.00 0.00 0.00 0.00 46.02 46.11 2gwp n GLY 14 CO 0.00 0.00 0.00 0.99 0.00 0.00 0.00 173.32 174.31 2gwp s ASP 15 N -0.49 0.74 -0.11 1.61 1.01 0.51 -4.25 116.67 115.69 2gwp s ASP 15 Ca 0.00 0.51 0.02 0.00 0.71 0.00 0.00 52.55 53.78 2gwp s ASP 15 Cb 0.00 -0.66 0.02 0.00 1.01 0.00 0.00 42.92 43.29 2gwp s ASP 15 CO 0.00 -4.22 -0.14 0.00 0.21 0.00 0.00 175.17 171.01 2gwp s ARG 16 N -5.52 2.12 0.29 8.23 1.70 -0.18 -4.88 118.95 120.70 2gwp s ARG 16 Ca 0.72 -0.52 -0.29 0.00 -0.47 0.00 0.00 55.73 55.17 2gwp s ARG 16 Cb -0.08 -1.82 -0.10 0.00 -0.57 0.00 0.00 34.95 32.39 2gwp s ARG 16 CO 0.56 -0.07 1.20 0.08 -1.08 0.00 0.00 175.30 175.98 2gwp s VAL 17 N 1.02 3.19 0.00 4.99 1.01 -1.26 -0.53 120.40 128.82 2gwp s VAL 17 Ca -0.06 1.17 0.00 0.00 0.00 0.00 0.00 61.98 63.09 2gwp s VAL 17 Cb -0.15 -3.74 0.00 0.00 0.00 0.00 0.00 36.38 32.49 2gwp s VAL 17 CO -0.02 0.27 0.00 0.54 0.00 0.00 0.00 175.10 175.89 2gwp n ARG 18 N 1.24 0.00 0.00 2.72 5.12 -0.04 -4.90 116.66 120.79 2gwp n ARG 18 Ca 0.00 0.00 0.00 0.00 -1.93 0.00 0.00 57.85 55.92 2gwp n ARG 18 Cb 0.44 -0.91 0.00 0.00 -1.16 0.00 0.00 32.46 30.82 2gwp n ARG 18 CO 0.00 0.00 0.00 0.41 -1.93 0.00 0.00 177.63 176.11 2gwp n GLY 19 N 3.18 0.97 3.92 -0.13 0.00 -0.63 -5.01 105.19 107.48 2gwp n GLY 19 Ca 0.00 -0.55 -0.31 0.00 0.00 0.00 0.00 46.02 45.17 2gwp n GLY 19 CO 0.00 0.00 0.00 -0.51 0.00 0.00 0.00 173.32 172.81 2gwp s THR 20 N -1.90 5.35 -0.17 2.61 -4.23 -1.26 -0.08 115.64 115.96 2gwp s THR 20 Ca 0.00 -0.34 -0.05 0.00 -1.18 0.00 0.00 61.69 60.12 2gwp s THR 20 Cb 0.00 -3.64 -0.09 0.00 1.34 0.00 0.00 72.50 70.12 2gwp s THR 20 CO 0.00 0.11 -0.20 0.00 -0.54 0.00 0.00 174.62 173.99 2gwp n GLY 22 N 2.20 1.48 3.55 0.00 0.00 -0.85 -4.95 105.19 106.62 2gwp n GLY 22 Ca -0.33 -0.53 -0.33 0.00 0.00 0.00 0.00 46.02 44.83 2gwp n GLY 22 CO 0.00 0.00 0.00 -0.26 0.00 0.00 0.00 173.32 173.06 2gwp s ILE 23 N -1.86 3.12 -0.67 -0.61 -4.36 -1.26 -1.51 121.20 114.05 2gwp s ILE 23 Ca 0.00 0.03 0.00 0.00 -0.26 0.00 0.00 60.65 60.42 2gwp s ILE 23 Cb 0.00 -3.32 0.00 0.00 1.25 0.00 0.00 42.46 40.39 2gwp s ILE 23 CO 0.00 -0.30 0.00 0.54 0.24 0.00 0.00 174.94 175.42 2gwp n ARG 24 N 9.02 -0.51 -5.14 0.37 5.12 -1.26 -4.99 116.66 119.27 2gwp n ARG 24 Ca 0.34 0.57 -0.30 0.00 -1.93 0.00 0.00 57.85 56.53 2gwp n ARG 24 Cb 0.52 -4.40 -0.16 0.00 -1.16 0.00 0.00 32.46 27.26 2gwp n ARG 24 CO 0.00 0.00 0.00 -0.06 -1.93 0.00 0.00 177.63 175.64 2gwp s PHE 25 N -2.29 2.19 0.17 -1.55 0.40 -0.57 -0.37 117.98 115.96 2gwp s PHE 25 Ca 0.00 -0.61 0.09 0.00 -0.60 0.00 0.00 56.93 55.81 2gwp s PHE 25 Cb 0.00 -1.44 -0.04 0.00 0.51 0.00 0.00 43.02 42.05 2gwp s PHE 25 CO 0.00 -0.17 -0.11 -0.51 0.70 0.00 0.00 175.22 175.13 2gwp s LEU 26 N -0.18 2.94 -0.32 -0.37 1.02 0.12 -0.04 118.68 121.84 2gwp s LEU 26 Ca -0.01 -0.57 -0.08 0.00 0.02 0.00 0.00 54.13 53.48 2gwp s LEU 26 Cb -0.12 -1.65 0.01 0.00 0.02 0.00 0.00 46.19 44.45 2gwp s LEU 26 CO 0.02 0.12 0.13 -0.47 0.02 0.00 0.00 176.35 176.17 2gwp s TYR 27 N -1.62 3.19 0.05 0.29 5.04 0.89 -0.45 117.35 124.74 2gwp s TYR 27 Ca 0.24 -0.95 0.00 0.00 -2.44 0.00 0.00 57.07 53.93 2gwp s TYR 27 Cb -0.09 -2.32 -0.03 0.00 0.35 0.00 0.00 41.96 39.86 2gwp s TYR 27 CO 0.15 -0.59 -0.04 0.00 -1.34 0.00 0.00 175.55 173.72 2gwp s PRO 30 N 0.65 4.18 0.00 0.00 0.04 -1.26 -1.01 135.00 137.60 2gwp s PRO 30 Ca 0.17 2.47 0.00 0.00 0.04 0.00 0.00 61.00 63.67 2gwp s PRO 30 Cb -0.13 -3.02 0.00 0.00 0.04 0.00 0.00 34.50 31.39 2gwp s PRO 30 CO 0.05 -0.47 0.85 -2.13 0.04 0.00 0.00 177.00 175.33 2gwp n ARG 31 N 1.17 0.00 -0.70 4.56 3.00 -1.26 0.30 116.66 123.74 2gwp n ARG 31 Ca 0.03 0.37 0.00 0.00 -0.00 0.00 0.00 57.85 58.25 2gwp n ARG 31 Cb 0.39 -1.35 0.00 0.00 0.00 0.00 0.00 32.46 31.50 2gwp n ARG 31 CO 0.00 0.00 0.00 -2.13 0.00 0.00 0.00 177.63 175.50